Santa Monica Pellet Stove Repair for Ignition, Feed & Shutdown Problems

Augers, igniters, blowers, sensors and control boards repaired, and the vent cleaned so the stove breathes. Written quote first.

  • Written quote first
  • Model-matched parts
  • Photo proof
  • Open 24 hours

Book Pellet Stove Repair

Request pellet stove repair in Santa Monica. We call to confirm a time.

No spam. We only use this to schedule your visit.

Pellet Stove Repair in Santa Monica, CA

Bottom line

Pellet stoves are part heater, part machine. When one won't ignite, stops feeding or shuts down with an error, Jimmy's Chimney Sweep handles pellet stove repair in Santa Monica. We repair augers, igniters, combustion and room blowers, sensors and control boards, and we clean the vent so the stove breathes. You get a written quote before parts are replaced. Call (747) 335-2794.

Pellet stove repair in Santa Monica calls for a different skill set than fireplace work. A pellet stove burns compressed wood pellets. A motor-driven auger feeds them, an electric igniter lights them, and a combustion blower pulls air through the fire and out the vent. Sensors and a control board run the whole thing. When any one of those parts fails or gets dirty, the stove stops. The good news is that most problems trace back to a short list of causes.

Common Pellet Stove Problems We Fix

Stove won't ignite

A failed igniter, ash buildup in the burn pot, or blocked airflow can all keep pellets from lighting. Igniters are a wear part and usually need replacing every few seasons with regular use.

Pellets not feeding

A jammed or seized auger, a failed auger motor, a tripped safety switch, or poor-quality pellets that leave too many fines (dust) can stop the feed. Humid coastal air can also swell pellets stored in a garage, which jams the auger.

Stove shuts down or shows an error code

Shutdowns usually come from safety sensors, such as the vacuum switch, low-limit or high-limit sensors, responding to a real problem. That's often a dirty vent or a weak combustion blower. We read the code, find the cause, and fix that, rather than just resetting the stove.

Noisy or failed blowers

Grinding, squealing or a fan that won't spin means the combustion blower or room blower is failing or packed with ash.

Smoke, soot or a lazy flame

A lazy, dark or sooty flame means poor airflow. It's usually a dirty burn pot, blocked heat exchanger passages, or a clogged vent.

Rustic room with a stove and a sunlit window
Most pellet stove problems trace back to a short list of causes.

Pellet Stove Repair Services and Sub-Services

Igniter replacement

We test and replace igniter elements with parts matched to your stove model.

Auger and auger motor repair

We clear jams, clean the auger tube, and replace failed motors or shear pins.

Combustion and room blower repair

We clean, repair or replace blower motors and check the seals.

Sensor and control board diagnosis

We test vacuum switches, thermal sensors and boards with a meter, then replace only what has failed.

Full pellet stove cleaning and service

This is a complete teardown cleaning. It covers the burn pot, ash pan, heat exchanger tubes, blowers, hopper and the passages behind the firebox. Most problems are prevented by an annual service.

Pellet vent cleaning

Pellet vents are small-diameter pipes that fill with fine ash. We clean the vent from end to end and check the termination outside. Our chimney cleaning team handles pellet stoves vented into a masonry chimney.

Close-up of a black stove door handle
Parts are tested with a meter and matched to your stove model.

Why Annual Service Matters for Pellet Stoves

Pellet stoves leave fine ash in places you can't reach with a vacuum. As the ash builds up, airflow drops, the stove trips its safety sensors, and parts like blowers and igniters wear out faster. A yearly professional cleaning, plus regular burn-pot and ash-pan cleaning by you, is the best way to avoid mid-winter shutdowns.

Our Pellet Stove Repair Process

  1. Diagnose: read error codes, test components, and check the vent and airflow.
  2. Explain: what failed and why.
  3. Written quote with parts and labor.
  4. Repair: replace parts and clean the airflow paths.
  5. Test burn: run a full start-up cycle and confirm feed and flame.
  6. Tips: pellet storage and cleaning habits that prevent repeat problems.

Pellet Storage Tips for Coastal Homes

  • Store pellet bags off the floor, in a dry spot, not in a damp garage corner
  • Keep opened bags sealed
  • Sift out fines (dust) before adding pellets to the hopper
  • Use quality pellets with low ash content
Close-up of compressed wood chips
Dry, low-ash pellets keep the auger feeding smoothly.

Repair or Replace Your Pellet Stove?

Most pellet stoves are worth repairing. Parts are widely available and repairs are usually modest. Replacement makes sense when the firebox or heat exchanger is cracked, the control board is discontinued, or repairs keep stacking up. If you're replacing, we'll walk through options, including a move to gas or a wood stove where allowed.

Power Outages and Pellet Stoves

Pellet stoves need electricity to run. A sudden outage can leave smoke in the stove because the blower stops. Ask us about battery backup units that keep the blowers running long enough for a safe shutdown.

Pellet Stove Repair FAQs

How often should a pellet stove be serviced?

Once a year, plus burn-pot cleaning by you every day or two of use.

Why does my pellet stove keep shutting off?

Usually a dirty vent or burn pot tripping a safety sensor. Cleaning often fixes it, and if not, we'll test the sensors.

Do you service all pellet stove brands?

We service the major brands. For less common models, we'll confirm parts availability first.

Pellet stove acting up? Book pellet stove repair in Santa Monica: (747) 335-2794.

Written by the Jimmy’s Chimney Sweep team

Local chimney and fireplace technicians at 2106 Wilshire Blvd, Santa Monica, CA 90403. We follow NFPA 211 and CSIA practices, and every recommendation on this page comes with photos and a written price. Last reviewed: November 2026.

Book Pellet Stove Repair in Santa Monica

  • Written quote first
  • Model-matched parts
  • Photo proof
  • Open 24 hours
Prefer to talk? Call (747) 335-2794

Jimmy’s Chimney Sweep · 2106 Wilshire Blvd, Santa Monica, CA 90403 · Directions

Request Your Visit

Takes 30 seconds. We'll call to confirm.

No spam. We only use this to schedule your visit.

Scroll to Top